The Model 20-CTR is designed
to monitor the whole house load, inverter output, generator output, etc. The
meter consists of a easy to install current transducer (CT) (2 for 2 phase 240
vac applications), a base module and an attractive oak trimmed panel mount display.
The remote display can be mounted up to several hundred feet from the base module
using inexpensive CAT5 LAN cable (can be provided). The meter features both
a "permanent" and resettable kw-hr and cost display, as well as watts,
peak watts and cost information (similar to the Model 4 series). The meter can
be configured for 120 or 120/240 operation and will monitor up to 9999 watts.
Digital Power Meter: Interior Wall Mounted, Remote Display
Installation Instructions
General Description:
The metering instrument consists of two general components: a surface
mount base unit for connecting to AC voltage and AC current and a remote, flush
mounted display unit. The base and display are connected using standard CAT-5
LAN cable. AC current is monitored using a standard snap on current transducer
(CT). AC voltage is sensed via two fused input lines to a step down transformer
(located inside the base unit).
Installation:
Locate the base unit as close to the supply as possible. Plan for
routing of the CT and the two fused voltage sense wires. The connections are
provided with a polarized 4 connector plug to the base unit. The remote display
may be mounted up to 100 ft from the base unit. Attach the CT around either
the Line or Neutral (for 120 vac systems), or L1 and L2 (for 240 vac systems).
Generally install the CT with the label toward the source. Connect the two fused
voltage sense wire across the output of the system.(120vac L1 and Neutral; 220vac
L1,L2). These wires are shipped with no end preparation. Attach ring connectors,
plugs or strip back bare end as installation requirements dictate. A phase reverse
jumper at the display can be used to correct any phase reversal caused by installation
configuration. The base unit has an LED, which will illuminate when ac voltage
is present. The display is designed to mount in a standard triple gang electrical
box, or equivalent. Route up to 100 ft of CAT 5 cable from the base unit to
the display. Connect the base unit to the display by plugging in the CAT 5 cable
into the RJ-45 jacks on the base and display units. Energize the system. If
voltage is present at the display unit, the LED on the display unit will illuminate.
If the system does not read proper power indication when the system is producing
power, change the position of the jumper on the back of the display unit. The
jumper must be on two of the three pins. The meter begins operation as soon
as it is energized.
| MODEL | 4-1850 | 20-1850, 21-1850CI and 20-1850CI | 20-CTR Whole House |
| FEATURE | RANGE | RANGE | RANGE |
| Backlit LCD | YES | YES | Option |
| Input Limits | 15 amps/120 vac | 15 amps/120 vac | 40 amps/240 vac |
| WATTS | 0-1850 | 0-1850 | 0-9999 |
| KW-HOURS | .001-9999 | .001-9999 | .001-65,500 |
| USER COST (c/kwhr) | 0-.99 | 0-.99 | 0-.99 |
| Avg Monthly Cost | YES | YES | YES |
| AMPS RMS | n/a | .20-15.00 (+/-3%)* | n/a |
| VOLTS RMS | n/a | 100-130.0 | n/a |
| POWER FACTOR | n/a | 0.00-1.00 (+/- 5%) | n/a |
| VARS | n/a | 20-1850 (+/- 5%)* | n/a |
| VOLT-AMPS | n/a | 20-1850 (+/- 5%)* | n/a |
| PEAK
WATTS/AMPS/VOLTS MINIMUM VOLTS |
n/a | YES: 20-1850 21 AND CI: WATTS ONLY |
WATTS ONLY |
| MEMORY (Kw-hrs ,cost, timer) | YES | YES | YES |
| ELAPSED TIME | YES | YES | YES |
| ACCURACY
(accept as noted) |
+/- 2% +/- 2 lsd | +/- 1.5% +/-2 lsd | +/- 2% +/- 2 lsd |
| Sample memory (average power during interval) | n/a | 8121 samples (21-1850CI) | n/a |
| Sample Interval | n/a | 1 min- 2 hours (21-1850CI) | n/a |
| RS-232 specs | n/a | 8N1, 9600 bps (21-1850CI and 20-1850CI) | n/a |
| Real
time clock/calender Battery backup |
n/a | 21-1850CI only | n/a |
| User Recalibration Capability | YES | YES | YES |
Operating Instructions
Your inverter output
remote display has 4 pressure sensitive switches:
,, [>]. and [<].
Initial Display:
The initial display on power up or when the Reset button is pushed
shows two values: the Watts being produced now and the lifetime generated
output in KW-HRS (Kilowatt hours).
Changing Displays:
Pressing the [>] and [<] keys will move the display through
several modes. Note: Pressing at any time will return the unit to
the Initial Display. Should the meter appear to lock up, press to
clear.
User Settings:
1. Pressing the [>] switch will display the dollar value of
electricity produced and the cents per KWHR used in the calculation. The
value of generation produced is permanently stored in memory. The unit cost
value, cents/kwhr, is user programmable from this screen. Press
to enter into the change mode. Press the [<] or [>] keys to change
the value. Press to set the value. Pressing the switch to
enter the change mode will display the value to 1/10th of a cent. This more
precise value is the number used in calculating dollar values. Press
twice to view the change mode and the cents/KWHR in 1/10th cents and return
to the display mode without changing the setting.
Note: The normal display mode shows costs in whole cents.
2. Pressing the [>] switch a second time will cause the unit to display Peak Watts. Pressing the switch will remove the stored value from memory. The Peak Watts displayed is the value of Peak Watts that the system produced since the last time the value was cleared from memory by pressing the switch.
3. Pressing the [>] switch a third time will cause the unit to display the dollar value of electrical generation and the KWHRs produced since the last time the memory was cleared. Clear memory was pressing the switch while in this display mode. Some users may choose to register on the first day of each month to show the dollar value and the KWHRs produced each month.
4. Pressing the [>] switch again will return the display to the Initial Display.